Diabetic Retinopathy Severity Grading (EfficientNetB0 + CBAM)

Five-class ETDRS severity grading from retinal fundus photographs.

Author: H.W.P.S.M. Wijenayake Project: NeuroGSD - AI Based Early Detection System for Common Eye Diseases Institution: Faculty of Information Technology, University of Moratuwa, Sri Lanka Supervisor: Dr. L. Ranathunga Domain expert: Dr. K. M. P. K. Bandara

Classes

0-No DR | 1-Mild NPDR | 2-Moderate NPDR | 3-Severe NPDR | 4-PDR

Architecture

EfficientNetB0 (ImageNet) + CBAM channel/spatial attention + global average pooling + dropout(0.4) + softmax. Two-stage transfer learning: frozen backbone first, then fine-tuning from block5a with BatchNorm layers held frozen.

Files

File Input size Gaussian sigma
dr_448.keras 448x448 20
dr_224.keras 224x224 10

config.json holds the full preprocessing specification. Preprocessing must match exactly - the model expects Ben Graham enhanced images, not raw fundus photographs.

Preprocessing

  1. Crop black border (intensity threshold 7)
  2. Resize to the model's input size
  3. Ben Graham enhancement: addWeighted(img, 4, GaussianBlur(img, (0,0), sigma), -4, 128)
  4. Rescale by 1/255

Results (held-out test set, n=262)

Configuration Accuracy QWK Macro-F1
224px argmax 0.6718 0.6209 0.4783
448px argmax 0.6985 0.7420 0.5700
448px + TTA (deployed) 0.7176 0.7695 0.5722
448px + 224px ensemble 0.7290 0.7848 0.5775

Per-class recall for the deployed configuration: No DR 0.876, Mild NPDR 0.122, Moderate NPDR 0.750, Severe NPDR 0.727, PDR 0.400.

Referable DR (classes 2-4 vs 0-1), 448px argmax configuration: AUC 0.942, sensitivity 0.838, specificity 0.923.

91.2% of predictions fall within one severity grade; 0.0% are misgraded by three or more.

Training data

1,744 fundus images at 512x512 native resolution, stratified 70/15/15 split (1220 / 262 / 262). Class counts: No DR 1017, Mild NPDR 270, Moderate NPDR 347, Severe NPDR 75, PDR 35. Imbalance ratio 29:1, addressed with square-root-smoothed class weights.

Limitations

  • Mild NPDR recall is 0.39.
  • PDR results are unreliable (n=4).
  • Severe NPDR (n=11) is also low-support; its 0.727 recall is indicative only.
  • Single-source dataset; generalisation across cameras and populations is untested.
  • Severity labels were graded by H.W.P.S.M. Wijenayake under the domain expert's guidance and subsequently reviewed and confirmed by him - not independently double-graded.

Statistical caveats

With 262 test images the 95% confidence interval on accuracy is approximately +/-5.5 percentage points. Stratified 5-fold cross-validation over all 1,744 images is planned to give more reliable per-class estimates.

The 448px + TTA configuration was deployed rather than the marginally higher-scoring ensemble: the 1.1-point accuracy difference amounts to 3 images and falls within the confidence interval, while the ensemble doubles inference cost and requires two parallel preprocessing pipelines.

Intended use

Research and educational use only. This model is not a medical device and must not be used for clinical diagnosis. Any screening deployment would require prospective clinical validation and regulatory approval.

Downloads last month
76
Inference Providers NEW
This model isn't deployed by any Inference Provider. 🙋 Ask for provider support